Printronix T4M - Calibrating the Media Sensor
You need to calibrate you media sensor to the type of media (labels) you are using - especially if you have just changed the sensor detection settings.

- Load ribbon and labels
- Place printer offline and press menu button
- Press return on sensor setup
- Press down key to highlight Run Auto Cal
- Press return key, the printer will feed a few labels and display the sensed distance, this should be close to the value you entered for the form length.
- Press the X key and return the printer online and test.
To save your changes:
- Press offline then menu key
- Scroll to the configuration icon and press enter
- Use the left and right buttons to select a configuration to save to, Save config: 1 as an example.
- Press return. Printer will display saving configuration.
- Load your new config, scroll to the config you wish to load, config 1 as an example and press return, Loading saved configuration will display.
- Press the X and return the printer online and test.
Service
Repair: We demonstrate an extremely high level of technical expertise and service for a wide range of Printer Products. We can repair onsite or in our workshop. We can also select and help install printers for our customers.
Maintenance: Datatrade offer a flexible approach to maintenance and can tailor a contract to suit your needs.
Hardware: We can supply printers, printheads, print servers etc… For further information on finding the right printer please use our Hardware Selector or contact us using the details below.
Consumables: We can provide a large range of cost effective consumables for Thermal, Impact and Laser printers.
In addition to supplying these items, we will also work with you to ensure you are using the correct product for quality and cost effectiveness.
For further information please Ring +44(0)1604 66-66-06 or email us.
For further contact details please Click Here